Description
Capacities: 3T / 5T / 10T / 20T
Rated output:2.0mv/v,3.0mv/v
Grade/Accuracy:C3 OIML R60
Material of elastomer: Alloy steel or stainless steel
Dimensions (mm)

Specification
| Item/Parameter | C3 | Unit |
| Rated load (Emax) | 3,5,10,20 | t |
| Maximum numbers of load cell | 3000 | d |
| verification Intervals |
| Minimum numbers of load cell | 0.01 | % of rated load |
| verification Intervals |
| Rated output | 2.0±0.1% | mV/V |
| Combined error | 0.015 | ±% of rated output |
| Temperature effect on sensitivity | 0.0012 | ±% of rated output/°C |
| Temperature effect on zero balance | 0.0008 | ±% of rated output/°C |
| Zero balance | 1 | ±% of rated output/ |
| Input resistance | 385±5 | Ω (Ohms) |
| Output resistance | 351±2 | Ω (Ohms) |
| Insulation resistance | ≥5000 | MΩ(Mega-Ohms) |
| Safe overload | 150 | % of rated capability |
| Ultimate overload | 300 | % of rated capability |
| Operating temperature range | -20~+70 / -20~+160 | C/F |
| Recommend excitation | 8~12 | V(DC or AC) |
| Maximum excitation | 18 | V(DC or AC) |
| Material of elastomer | Alloy steel |
| Protection class | IP67/IP68 |